A major addition in 1972 added masonry, cast-in-place concrete, metal panels, aluminum-framed glazing, and metal roofing. The main roof types include a 2-ply modified bitumen roof assembly and a protected membrane assembly.
RDH coordinated with the structural, electrical, and architectural consultants to prioritize our recommendations: Replace the membrane or use a surface-applied coating to mitigate short-term leaks.
We began by assessing all enclosure components and assemblies and the identification items requiring maintenance and/or renewal. The comprehensive summary was sorted into complementary groups with respective cost estimates to facilitate budgeting.
A key upgrade of the building’s exterior enclosure was focused on addressing the exterior insulation at concrete soffits to manage interior temperatures and mitigate condensation.
RDH also helped oversee the implementation of recommendations by developing specifications, reviewing submittals, and performing field reviews of work on-site with the General Contractor.